| Input Selection | Typical Application |
Signal Conditioner |
|
| Description | Model(Channels) | ||
| DC Voltage
or Current (V, mV, A, mA) |
- Voltage/current scaling - Isolation - Buffering - Noise reduction - Measuring peak singnals - Ramp control |
Isolator, field configurable |
AP4300 |
| AP4380-2000/AP4380-2001 AP4382 (single) |
|||
| AP4390/AP4391/AP4392 (dual) | |||
| DC to Frequency | AP7500/7501 | ||
| Track-Hold / Peak-Hold Process Function |
AP4570 | ||
| DC Programmable Up / Down Ramp Generator | AP4830 | ||
| AC Voltage or Current
(V, mV, A, mA) |
- Voltage/current
scaling - Isolation - Buffering - Noise reduction |
Isolator, field configurable | AP6380 |
| Thermocouple (Types E, J, K, R, S, T, B) |
- Temperature control
- Isolation - Monitoring - Data acquisition |
Isolator, linearizing & field configurable | AP4351 |
| RTD (Types PT, NI CU) | - Temperature control - Monitoring |
Linearizing / Non-Linear | AP4151-2000 |
| Potentiometer (0-100 ohm to 0-100K ohm) |
- Tank level control - Monitoring - Data acquisition - Resistance position - Sensor and setpoint conditioning. |
General purpose | AP4003-0001 |
| LVDT | - Control, display, and recording of motion. | General purpose | AP6050 |
| Frequency
|
- Flow - Velocity control or monitoring - Motor speed control - Scaling - Pulse accumulation - Integration - Totalization |
Isolator, field configurable | AP7380 |
| DC to frequency | AP7501 | ||
| Frequency Scaler | AP7510 | ||
| Strain Gauge
(1, 2, 3, 5, 10, 20 mV/V, 5V-10V Excitation) |
- Pressure control - Pressure status monitoring - Load cell/weight conditioning -Load cell/pressure data acquisition. |
Isolator, field configurable | AP4081 |
| Slidewire (100 ohm to 0- 100K ohm) |
- Motorized valve
control - Damper - Feedback on/off control |
Valve-Positioner/Controller | AP3200 |
| Power
Supplies (also see Ultra SlimPak) |
- Current loop supply, excitation. | 24VDC supply | AP9046 |
|
Signal conditioners amplify and condition weak signals generated by process sensors. They send signals long distances without being degraded by electrical noise. They are also used to drive useful devices such as indicators, alarms, controllers, computer interfaces and other process instrumentation. AP4000 - AP9000
Series The 4000 Series provides a complete line of interface and conditioning for temperature, pressure, flow, load and other process-sensing devices. Four-Wire
Transmitters Isolation Isolation eliminates existing and potential ground loops, eliminates common mode voltage and checks power surges. Also, isolation simplifies the connection of loop elements by eliminating the need for special grounding systems. Input
Selection DC Voltage or Current Three-Year &
Lifetime Warranties |