WV905 DIN Rail Mount Power Supply |
TECHNICAL SPECIFICATION (WV905) |
| Input Voltage |
Typical: |
|
115 to 239VAC,
±10%, 50/60Hz |
|
Minimum: |
|
85VAC, 120VDC |
|
Maximum: |
|
265VAC, 300VDC |
| Input
Current |
@115VAC: |
|
250mArms,
±20% |
|
@230VAC: |
|
150mArms, ±20% |
|
@125VDC: |
|
125mA,
±20% |
|
@250VDC: |
|
65mA, ±20% |
| Output
Voltage |
|
|
24VDC |
| Maximum
Output Current |
|
0.5A |
| Input
Protection |
Fuse: |
|
2A slowblow
(internal) |
|
Inrush
Current: |
|
Thermistor |
|
Over Voltage: |
|
Varistor |
| Switching
Frequency |
|
100kHz |
| Efficiency @ Maximum Load |
|
79% |
| Maximum Ripple |
|
|
0.1% |
| Load
Regulation |
|
|
0.2% (10% to
100% Load) |
| Line Regulation |
|
|
0.2% (85VAC to 265VAC In) |
| Overload Protection |
|
Over current
shutdown with automatic restart plus thermal shutdown |
| Maximum Load
Capacitance on Output |
|
5.000uF |
| Hold
Time |
|
(full output
current after loss of input) |
|
@115VAC: |
|
14ms |
|
@230VAC: |
|
70ms |
| Isolation |
Input to
Output: |
|
3kV |
|
Input/Output to Rail: |
|
4kV |
|
Input to Ground: |
|
1.5kV |
|
Output to Ground: |
|
500V |
| Wire Size |
|
|
26-12AWG (0.1 to 4.0mm2) |
| Operating Temperature |
|
-20°C to
+50°C (-4°F to 122°F) |
| Storage
Temperature |
|
-40°C to +85°C
(-40°F to 185°F) |
| Operating Humidity |
|
20% to 85%
RHNC @ 45°C |
| Storage
Humidity |
|
20% to 90% RHNC @ 60°C for
24 hours |
| Size |
|
|
DIN rail
case refer to Dimensions drawing |
| Agency
Approvals |
|
UL, CSA, CE mark |
|