| Input Selection | Typical Application | Product Selection |
| Universal Input | ||
| DC Voltage or Current (V, mV, A, mA) Includes optimum filtering, and conditioning to reduce susceptibility to transients and signal noise. |
Remote data acquisition, intrinsic Safety, current to pressure and isolation which provides equipment & personal protection. | T700 (loop
isolator) T703 (wide ranging) T280 |
| Thermocouple (Types B, C, E, J, K, N, R,S, T) Includes encapsulated cold-junction compensation (CJC) and sensor burnout detection |
Remote temperature data acquisition, intrinsic safety and isolation which provdes equipment and personal protection. | T723 (wide
ranging) T280 T797/8 (programmable/Hart) |
| RTD (Type PT, NI110, CU10) Includes DC excitation supply for 3-wire RTD resistance sensors and sensor burnout detection T797/8. |
Remote temperature data acquisition, BTU transfer rate, intrinsic safety and isolation which provides equipment and personal protection. | T713 (wide
ranging) T797/8 (programmable/Hart) T280 |
| Potentiometer (50 ohm to 200K ohms) Includes excitation supply for 3-wire potentiometer or slidewires, to minimize circuitry at the sensor. |
Remote tank level data acquisition, setpoint transmission, resistance position sensor conditioning and isolation which provides equipment and personal protection. | T752 (wide
ranging) |
| Frequency (0-50Hz to 0-10KHz) Includes 50% or greater span "turndown" adjustability. accepts input amplitudes from 100mVpp to 20Vrms. |
Motor/pump speed, remote flow data acquisition, intrinsic safety and isolation which provides equipment and personal protection. | T773 (wide ranging) |
| AC Voltage or Current (V, mV, A, mA,) Includes optimum filtering, and conditioning to reduce susceptibility to transient and noisy operation. |
Remote AC data acquisition, AC motor status control and isolation which provides equipment and personal protection. | T761 (wide ranging) |
|
Transmitters are used to amplify and condition the very small electrical signals which are generated by sensors as they measure the physical variables of a process. Once conditioned to usable levels, these signals are used to drive other instrumentation such as industrial computers, dataloggers, chart recorders, alarms, panel meters and controllers. The TransPak
Series Two-Wire
Transmitters Intrinsic Safety
Due to their low energy consumption and storage, two-wire transmitters are the only types of transmitters considered for intrinsically safe applications. Many of Action's TransPaks are Canadian Standards Association (CSA) and CENELEC approved for intrinsically safe operation in hazardous - even explosive - environments when installed in accordance with the manufacturer's drawings. Input Selection DC Voltage or Current Three Year Warranty |
| Last Updated Tuesday, April 08, 2008 | |||