- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  

T287
Programmable Isolating Universal Input 2-Wire Transmitter


TECHNICAL SPECIFICATION (T287)
Input Types Thermocouples: Most standard types & all special types using customer defined tables & polynomials.
RTD: 2-, 3- & 4-wire, Pt-100, Ni-110, Ni-120 & other RTDs. Includes Callandar-Van-Dusen adaptation and custom sensors linearization with user defined tables and polynomials.
DC mV: -10 to 100mV
Potentiometers: 0 to 20k Ohms
Resistance: 0 to 400 Ohms
General Specifications
Minimum Range: 2mV
Output: 4-20mA
Supply Voltage: 9-40VDC @ no load, reverse polarity protected
Maximum Load: Rmax = (Vsupply – 9V) / 20mA
Operating Temperature: -40 to 85°C
Storage Temperature: -55 to +125°C
Humidity: 0 to 95% RHNC
Response Time: 0.3 seconds, to 90% of input (>3 updates/sec)
Damping Factors: Programmable 0 to 64 seconds, to 0 to 120% of input range, using configuration software
Stability: Better than ±0.1% of span for 12 months
Isolation: 2000VDC, input to output
RFI Protection: <1% effect of span at 20-1000MHz and at field strength of 20V/m
Performance Specifications
Output Resolution: 0.015% of span (2.5uA)
Output Linearity (D/A): Better then 0.02% of output span
Sensor Linearization: Better than 0.1°C for RTDs
Better than 0.2°C for Thermocouple
Cold Junction Compensation: Automatic to within ±0.7°C for all thermocouples
Temperature Stability: 0.015%/°C combined zero and span.
Supply Voltage Effect: < ±0.003% per volt.
Calibration: Automatic, unit includes all calibration parameters. The unit performs periodic zero and span self-test, and auto calibration.
Input Linearity: Better than 0.01% of span (mV input)