DC Input, Digital Indicator
V438

Provides a Digital Display of Process Variables from DC Voltage and Current Inputs

  • Field Configurable Input Accepts 4-20mA, 1-5V, 0-5V and 0-10V Signals
  • 4 ½ Digit Display with Dummy Zero for 501 to +199990 Count Spans
  • 4 Visual Alarm Points with Front Panel LED Status Indication
  • Optional 2 Relay Output and 4-20mA Transmitter Output
  • Isolated 24V DC Excitation Source for 2-Wire Transmitter Inputs or the Optional 4-20mA Output
  • 11 Point Linearization and Square Root - Curve Fitting Functions
  • NEMA 4X Front Panel
  • Datasheet
  • Request Quote

The VisiPak model V438 is a versatile, field configurable, DC Current and Voltage input LED indicator which provides a NEMA 4X water tight front panel that fits 1/8 DIN cutouts. The four visual setpoint alarms are standard and annunciated via individual front panel LEDs.

Two form C relays are available as optional outputs for the first two setpoints. They can be configured as high or low, failsafe or non-failsafe. Each setpoint has a 100% adjustable deadband (or reset points) which can be effectively used in on/off control applications or as a latching alarms. An isolated 4-20mA transmitter output is also available as an option, with or without the two relays.

The V438 accepts 4-20mA, 1-5V, 0-5V and 0-10V inputs and displays any engineering scale required, between 501 and + 199990 counts with a programmable decimal for the full-scale span. There is an isolated 24V excitation source to power a two-wire transmitter or transducer.

Field configuration of the input range, alarm function, and analog transmitter output scaling is quick and easy since only one button is required to toggle through the selections. The indicator is factory calibrated to rated accuracy but can be checked and adjusted in the field if necessary, using the same configuration button.

A second front panel button is used for acknowledgement of alarms. This button can be pushed to unlatch or reset the optional output relay. For remote acknowledgement, terminals are provide to allow wiring of a switch to a different location.

To prevent tampering and ensure safety a lockout jumper is used to limit access to the configuration button functions. When the lockout mode is enabled, only alarm setpoints and output scaling functions are displayed and they can not be altered without moving the lock jumper.